SCADASuite Release Notes
October 12, 2020
- Update SCADASuite Management to reduce issues with alt-tab. This should also mitigate the issue where the application sometimes crashes after losing focus or remaining idle.
- Changed SCADASuite Management version to 3.40.
May 25, 2020
-
For Plunger Lift config version 1.4.2, app version 1.4.4
- Reset the consective plunger no-arrival counts that are used for recovery mode when recovery mode is disabled or Plunger Exists is unchecked. This prevents the plunger lift program from getting stuck in recovery mode under certain operating conditions.
- Correctly calculate well flow and critical flow averages during post-arrival injection when the Post Arrival Injection Mode is Continuous Variable Flow.
- Inject gas during pre-arrival injection even if the previous plunger arrival type is unknown. Normal arrival injection settings will be used and normal arrival injection must be enabled for gas to actually be injected.
- Configuration version is unchanged from the previous release. To get the fix, make sure to use app version 1.4.4.
- Changed SCADASuite Management version to 3.39.
May 11, 2020
-
For Plunger Lift config version 1.4.2, app version 1.4.3
- The optimized set point for the Critical Flow Shut In Condition is now decreased on very early plunger arrival and increased on very late plunger arrival. Previously, adjustments were reversed.
- Configuration version is unchanged from the previous release. To get the fix, make sure to use app version 1.4.3.
- Changed SCADASuite Management version to 3.38.
April 29, 2020
-
For Plunger Lift config version 1.4.2, app version 1.4.2
- Fixed a bug with how the average well flow used by the Continuous Varible Flow gas lift mode is calculated.
- Configuration version is unchanged from the previous release. To get the fix, make sure to use app version 1.4.2.
- Changed SCADASuite Management version to 3.37.
April 28, 2020
-
For Plunger Lift config version 1.4.2, app version 1.4.1
- Fixed a bug where optimized values for the Casing/Line Pressure Difference and Tubing/Line Pressure Difference Flow Conditions was sometimes not calculated correctly.
- Configuration version is unchanged from the previous release. To get the fix, make sure to use app version 1.4.1.
- Changed SCADASuite Management version to 3.36.
April 27, 2020
-
For Plunger Lift config version 1.4.2, app version 1.4.0
- Allow the selection of Continuous Variable Flow for Post Arrival Injection when the Gas Lift Control Mode is Plunger.
- When the Advance to Flow command is triggered, the program will move to the Waiting for Plunger arrival state if the well has a plunger, otherwise the program will move to the After Flow Delay state.
- Changed SCADASuite Management version to 3.35.
April 8, 2020
-
For Plunger Lift config version 1.3.4, app version 1.3.0
- Add Continuous Variable Injection gas lift control mode. This allows injection of gas at a constantly changing rate that is automatically determined by the difference between the calculated critical flow and the measured well flow.
- Changed SCADASuite Management version to 3.34.
March 16, 2020
-
For Well Test config version 0.9.1, app version 0.9.0
- Add the option to export accepted test results to a CSV file on the RTU.
- Changed SCADASuite Management version to 3.33.
January 9, 2020
-
For Plunger Lift config version 1.2.2, app version 1.2.0
- Add a new type of critical flow calculation.
- For all applications: Removed the check for the "Updates Until" time while validating a license. Licenses are now good for all versions, regardless of when the license was generated. Use RTU application bundles compiled after January 8 to get this feature.
- Changed SCADASuite Management version to 3.32.
November 27, 2019
-
For MQTT config version 0.11.0, app version 0.11.1
- Fixed a bug where the EngLow value for float values was not sent correctly when using the Sparkplug B data format.
- Added the ability to import a Realflo Modbus Register Export file for use in a register overlap report. This lets you use only the registers from your specific Realflo configuration in an overlap report.
- Changed exe version to 3.31
November 17, 2019
- Rebrand to Gen7 Systems SCADASuite. This is a name change only. There are no functionality changes.
- Changed exe version to 3.30
October 30, 2019
-
For Plunger Lift config version 1.1.7, app version 1.1.0
- Add recovery mode. This allows the value of the Minimum Off Time flow condition to be adjusted if the number of consecutive plunger no arrivals exceeds a configurable limit.
- Add command parameters to allow the user to immediately advance to the After Flow Delay or after Shut In Delay states.
- Changed exe version to 3.29
October 11, 2019
-
For Well Test config version 0.8.0, app version 0.8.1
- Fixed a bug where events generated by Realflo were not acknowledged correctly by the Well Test application.
-
For MQTT config version 0.11.0, app version 0.11.0
- Increased the number of floating point values that can be published by 32, for a total 64 values.
- Changed exe version to 3.28
September 25, 2019
-
For Plunger Lift config version 0.21.0, app version 0.21.1
- When the Gas Lift Control Mode is Continuous Critical Injection, and the Sales Valve Action is enabled, and the Sales Valve Action is Shut In Injection, the program would try to control the well flow rate instead of the injection flow rate. This is now fixed and the program will control the injection flow rate when in this state.
- When a plunger control loop was disabled, but the associated gas lift control loop was enabled, the Valve Control Register would be written to. This is fixed and the Valve Control Register is only written to if the plunger control loop is enabled.
-
For Shutdown config version 0.4.1, app version 0.4.0
- Increase the number of outputs from 8 to 32.
- Changed exe version to 3.27
July 8, 2019
-
For Plunger Lift config version 0.21.0, app version 0.21.0
- Add an optional, configurable, action for gas lift when the plunger sales valve is closed and the gas lift control mode is Continuous Flow or Continuous Critical Flow.
- Changed exe version to 3.26
June 25, 2019
-
For Tank Volume config version 0.2.11, app version 0.2.0
- Initial release of RTU program. This is a beta release to test functionality and to gather feedback.
- Changed exe version to 3.25
June 10, 2019
-
For Plunger Lift config version 0.20.1, app version 0.20.1
- Fixed a bug where the gas lift program did not stop Shut In Injection correctly when the gas lift control mode override was disabled.
- Added buttons to delete remote app configurations, remote licenses, remote communications settings and remote files on the Database Sync tab in the PC Configuration program.
- Show the names of files that are in a remote file bundle on the Database Sync tab in the PC Configuration program.
- Changed exe version to 3.24
May 15, 2019
-
For Plunger Lift config version 0.20.1, app version 0.20.0
- When the gas lift application is in the Continuous Critical Injection mode the gas lift program will not hold off the plunger lift program and will not force the sales valve open.
- Moved the Well Flow Average Count configuration parameter from the Injection Register Settings group to the Injection Control settings group.
- Added support for exporting and importing licenses, ethernet communications settings and arbitrary files to the Database Sync tab in the PC Configuration Program.
- Changed exe version to 3.23
April 26, 2019
-
For Shutdown Manager config version 0.3.1, app version 0.3.0
- Added a configurable maximum override time for outputs.
- Added status information to indicate the elapsed time in override and the time remaining in override when an output is overridden.
- Fixed a bug in the overlap report where the register used by coils in a Telepace project file was sometimes not decoded correctly. This bug caused incorrect register overlap reports when a Telepace project file was included in the report.
- Changed exe version to 3.22
April 23, 2019
-
For Plunger Lift config version 0.19.4, app version 0.19.0
- The application will not read or write to any modbus registers after being copied to the RTU until a configuration is downloaded to the application.
- Add gas lift injection mode override. This allows the active gas lift injection mode to be temporarily overridden.
- Add a user configurable amount of averaging to the well flow rate that is used for gas lift. This helps with noise rejection and erroneous measurements.
- Improved injection control when using gas lift with modes where the injection set point is calculted using critical flow.
- Changed exe version to 3.21
March 17, 2019
-
For Plunger Lift config version 0.18.0, app version 0.18.1
- Fixed a bug where the Critical Flow Max Injection Flow value was not respected and the injection flow rate was allowed to exceed this value.
- Changed exe version to 3.20
March 14, 2019
-
For Plunger Lift config version 0.18.0, app version 0.18.0
- Fixed a bug where the pv for the gas lift injection flow PID control loop was read from the injection flow rate instead of the well's flow rate when using critical flow rate injection modes.
- Improved how PID control is restarted after being stopped for smoother injection valve actuation on restart.
- Raised the maximum allowable value for some timers for gas lift control.
- Changed exe version to 3.19
March 3, 2019
-
For Plunger Lift config version 0.17.4, app version 0.17.5
- Ensure that gas injection is stopped when the Gas Lift Control Mode is changed away from Plunger.
- Fixed a bug where the Gas Lift clamp active status wasn't cleared when the clamp was disabled.
- Fixed a bug where Gas Lift post arrival injection was only active during the after flow delay state.
- Improved how state changes are handled when Gas Lift is active and the plunger state changes.
-
For Shutdown Manager config version 0.2.16, app version 0.2.0
- Initial release.
- Use Shutdown Manager to process digital, integer and float input values to drive digital outputs.
- Use the Shutdown Manager export to verify the the logic as built matches the logic as designed.
- Asteriks are no longer added to names when application configurations are copied.
- Changed exe version to 3.18
Febraury 21, 2019
- Added the ability the import a Telepace Studio project file (*.tpj) for inclusion in the register overlap report.
- Fixed a bug where floating point values were sometimes not written correctly to the export file. This would make it impossible to import the file.
- Changed exe version to 3.17
- No RTU application changes
January 20, 2019
-
For Plunger Lift config version 0.17.4, app version 0.17.4
- Fixed a bug where the gas lift override value sometimes wasn't written to the user defined PID output register correctly.
-
For Well Test config version 0.8.0, app version 0.8.0
- Added Test Time status parameters which track the actual time that a well is under test.
- Changed exe version to 3.16
January 16, 2019
-
For Plunger Lift config version 0.17.4, app version 0.17.3
- Fixed a bug where shut-in injection for gas lift sometimes wasn't starting.
- When override for gas lift is disabled, the system moves from the overridden value to the controlled value smoothly, under PID control.
- Changed exe version to 3.15
December 26, 2018
- Fixed a typo in version 0.7.0 of Well Test where n-Decane in a gas composition was described as n-Heptane. All of the underlying functionality was correct, and continues to be correct. This change only affects the description in the PC Configuration Program.
- Changed exe version to 3.14.
- No changes were made to any RTU programs.
December 5, 2018
-
For Plunger Lift config version 0.17.4, app version 0.17.0
- Changed the Minimum Line Pressure Flow Condition to Maximum Line Pressure. The condition is now met when the actual line pressure is less than the threshold.
- Added partial plunger arrival time to history for all control loops. This value tracks the seconds portion of the plunger arrival time.
- Fixed a bug with Gas Lift in the Injection Steps mode. Exiting the step is now handled properly when the pressure increment is negative.
- Changed exe version to 3.13
November 27, 2018
-
For Plunger Lift config version 0.16.8, app version 0.16.0
- Change limits for Gas Lift Injection Flow Register and Gas Lift Injection Pressure Register to support 40000 registers.
- Remove Idle state from PID Control Modes for gas lift.
- Preserve plunger arrival counts and history when the control loop is disabled.
- Move flow and pressure set points for gas lift from control to configuration.
- Add Plunger Travel Preset register. This allows the calculated plunger travel to start at any value and preserves the total plunger across reboots.
- For gas lift, add the Critical Flow Max Flow setting to limit the injection flow rate set point when using critical flow to calculate the set point.
- Gas lift features are still in beta. Do not deploy gas lift on a well.
- Added a build of Well Test and Datalogs for SCADAPack 4203.
- Changed exe version to 3.12
November 5, 2018
-
For Plunger Lift config version 0.14.2, app version 0.14.2
- Changed the high limit for the Maximum Load Ratio Flow Condition in the Plunger Lift application to 100% from 50%.
- Changed exe version to 3.11
November 3, 2018
- Added Database Sync tab. Features on this tab let you export and import app configurations to and from an external database.
- Added a link to the new RTU Downloads document on the Help tab. This document links to all of the different application bundles and is updated as new bundles are released. This makes it possible for users to easily find older versions of RTU programs.
- Changed exe version to 3.10
- No changes to RTU applications
September 25, 2018
- Added support gas lift features to the Plunger Lift application. This is a beta release and is meant for testing and evaluation.
- Changed exe version to 3.9
- RTU applications are at build 434
September 22, 2018
- Made it easier to work with a large number of communications setting on the Sync and Test tabs.
- Added the ability to filter Compatible Apps by name on the Sync tab. This makes it easier to find a specific app configuration.
- Changed the high limit for the Maximum Load Ratio Flow Condition in the Plunger Lift application to 50% from 20%.
- Changed exe version to 3.8
- RTU applications are at build 432
September 5, 2018
- Added the ability to export an application glossary.
- Configuring mimics, which uses unsupported ViewX automation libraries, is now optional when exporting to ClearSCADA.
- Changed exe version to 3.7
- RTU applications are at build 423 (unchanged)
August 23, 2018
- Added support for extended Modbus addressing. This is a SCADAPack specific feature that allows for Modbus station addresses between 254 and 65534. This feature does not require any updates to the RTU programs.
- Changed exe version to 3.6
- RTU applications are at build 423 (unchanged)
August 15, 2018
- Fixed a bug in the PC Configuration Program where the values for coils and contacts were sometimes not displayed correctly on the Test tab.
- Changed exe version to 3.5
- RTU applications are at build 423 (unchanged)
July 22, 2018
- Reworked Plunger Lift so that it doesn't cause a memory leak in the RTU. The memory leak is not in SCADASuite, but in the RTU's firmware, however implementation specifics of SCADASuite can expose the firmware bug. The changes to Plunger Lift are purely internal and no changes to functionality were implemented.
- The previous version of Plunger Lift, build 418 (app version 0.13.0), should not be used.
- Fixed a bug in Datalogs where periodic logging would sometimes occur even when it wasn't enabled.
- Changed exe version to 3.4
- RTU applications are at build 423
July 16, 2018
- For datalogs (re)fixed a bug where INT16 values sometimes wouldn't be logged correctly depending on what types of values were in the neighboring fields.
-
For Plunger Lift
- Added casing/line pressure difference shut in condition including optimization.
- Added user defined protection setting.
- Show plunger arrival time for the current cycle in minutes and seconds, instead of just minutes.
- Export config version and app version to Modbus registers.
- Show license status in Modbus registers.
- Fixed a bug where temporary licenses were not decoded correctly.
- Fixed a bug where very early arrival shut in did not work properly.
- Changed exe version to 3.3
- RTU applications are at build 418
July 1, 2018
- Updated Simark logo.
-
For Datalogs
- Fixed a bug where INT16 values sometimes wouldn't be logged correctly depending on what types of values were in the neighboring fields.
- Added the ability to configure logging for all 8 fields in a datalog. Previously, the first field was dedicated to a timestamp.
- Added the ability to log a timestamp in any field in a datalog.
- Changed exe version to 3.2
- RTU applications are at build 415
May 30, 2018
- Fixed a bug where the PC Configuration Program would crash on Windows 7 when the locale wasn't set to US English.
-
For Plunger Lift
- Fixed a bug where the application would go to the Waiting For Plunger Arrival state on startup even when the application was not configured to use a plunger.
- Added additional validation to Flow Conditions and Shut In Conditions. At least one condition from each group must be enabled to avoid a configuration error.
- Enabled the Minimum Off Time Flow Condition and Maximum On Time conditions by default. This prevents a configuration error from occuring with the default configuration.
- Fixed a bug where the User Flow Condition Enable was configured via a holding register instead of a coil.
- Changed exe version to 3.1
- RTU applications are at build 410
May 24, 2018
- Rebrand to Simark SCADASuite. Update links, user manual, program text, etc.
- Add a 3 second post initialization delay to the MQTT application. This allows the force disconnect control parameter to be read properly when the RTU exits sleep mode.
- Improved the way that the force disconnect control parameter is used by the MQTT app. These changes will ensure that the MQTT app won't try to connect immediately after the configuration is changed or the application is restarted.
- Changed exe version to 3.0
- RTU applications are at build 401
May 2, 2018
-
For MQTT
- Explicitly set the quality to bad (0) on NBIRTH for datalog metrics. This prevents a 0 with good quality from being inserted into the historic record in Ignition. A 0 with bad quality, which is easy to filter, is inserted instead.
-
For Plunger Lift
- Critical flow is always calculated when a plunger control loop is enabled.
- Added total plunger travel calculation for each control loop. Added status parameters to show this value over Modbus.
- Changed exe version to 2.14
- RTU applications are at build 382
April 29, 2018
-
For Well Test
- Do not create a new daily record when calculations for a flow run in Realflo are stopped.
- Added additional logging during the Configure Realflo state.
- Read the current execution state correctly for Realflo runs 5 to 10.
- Automatically retry starting a test when a test fails to start. This will mitigate the issue where someone else tries to communicate with Realflo while Well Test is trying to start a test.
-
For Datalogs
- Add support for monitoring 32 bit integer values.
-
For MQTT
- Added support for datalogs containing 32 bit integer values.
- Fixed a bug where the NBIRTH message was corrupt when trying to upload both Limits and Units for float values. This did not affect other value types.
- Increased the number of datalogs that can be published from 4 to 8.
- Added the ability to publish datalogs on demand via a coil.
- Removed the RETAIN flag from all PUBLISH messages.
- Changed exe version to 2.13
- RTU applications are at build 378
April 20, 2018
-
For Mqtt
- Added support for publishing datalog data (timestamped historic data) when using the Sparkplug B format.
- Added standard node control metrics 'Rebirth' and 'Next Server' when using Sparkplug B.
- Fixed a bug where publishing a report group on demand would continiously publish the report group.
-
For Well Test
- Fixed a bug where the liquid configuration sometimes wasn't copied correctly from actual to desired registers.
- Changed exe version to 2.12
- RTU applications are at build 368
April 15, 2018
-
For Well Test
- Fixed a bug where flow rate was sometimes not read correctly from Realflo for runs greater than 4.
- Fixed a bug where the Time Left in Test was not presented correctly.
- Purge volumes are now cleared immediately when a new test is started.
- Changed exe version to 2.11
- RTU applications are at build 365
April 12, 2018 (2nd release)
- Fixed a bug in Well Test where control parameters were sometimes not initialized properly. This prevented tests from being started, stopped, accepted or rejected.
- Changed exe version to 2.10
- RTU applications are at build 363
April 12, 2018
-
For Plunger Lift:
- Cycle stats are preserved and updated correctly when exiting the Protected state.
- Fixed a bug where 'time since last reset' was being cleared when the reset command (not reset stats command) was issued.
- Improved the way that inputs are read from Modbus so that protection vi are detected quickly.
- Added Unix timestamps that show when the stats were reset.
- When a reset command is issued the application will go through its normal end of cycle routine, including updating cycle stats.
- Changed exe version to 2.9
- RTU applications are at build 361
April 11, 2018
- Fixed the memory leak issues described in the previous release of the MQTT application.
-
For MQTT:
- Added the ability to subscribe to changes when using the Sparkplug B format. Added associated enables, logging and status information.
- Added units to integer and float values. Units can optionally be pushed to the host when using Sparkplug B.
- Added support for up to 4 MQTT servers. Only one server can be connected at one time, but the app will cycle through available servers trying to connect.
- Changed connection timeout to 5s from approximately 30s.
- Added a control parameter to allow manual control of the MQTT connection. User programs can now easily control the connection to the MQTT server.
- Added an option to disconnect cleanly from the MQTT server.
- Improved the ClearSCADA export so that it no longer stops when the application uses the same Modbus register multiple times.
- Changed exe version to 2.8
- RTU applications are at build 359
April 4, 2018
- Reverted MQTT to config version 0.6.1 and app version 0.6.1. The newer version (0.7.4) works, but interacts with the RTU in such a way that a memory leak occurs as the RTU services inbound TCP/IP connections. Version 0.7.4 of the MQTT app can be used for testing, but cannot be used in production.
- We've left the user manual as is for now, since the new MQTT features will be released, but it will take a few more days.
- Reworked AppSuite base firmware to reduce an interaction with the RTU firmware where the RTU leaks memory as it services TCP/IP connections. To be clear, the leak is not in AppSuite, but in the RTU, however, the leak does not occur unless AppSuite is installed on the RTU. Our best guess is that the dynamic linking that occurs when the .out file is downloaded to the RTU is not working perfectly in some cases. This effect can be mitigated by careful design of the AppSuite firmware.
- Changed exe version to 2.7
- RTU applications are at build 355. MQTT was reverted to the same as build 342
April 3, 2018
- Fixed a bug where configuration and summary information was included in the CSV Export when it wasn't supposed to be.
- Reworked RTU program bundles to build smaller bundles with less apps. This will help with resource issues on the RTU.
-
For MQTT:
- Added the ability to subscribe to changes when using the Sparkplug B format. Added associated enables, logging and status information.
- Added units to integer and float values. Units can optionally be pushed to the host when using Sparkplug B.
- Added support for up to 4 MQTT servers. Only one server can be connected at one time, but the app will cycle through available servers trying to connect.
- Changed connection timeout to 5s from approximately 30s.
- Added a control parameter to allow manual control of the MQTT connection. User programs can now easily control the connection to the MQTT server.
- Added an option to disconnect cleanly from the MQTT server.
- Changed exe version to 2.6/li>
- RTU applications are at build 352
March 24, 2018
- Changed the default value and limits for the Constant Water Cut setting in the Well Test app.
-
For Plunger Lift:
- Added status parameters to show minimum casing pressure, casing pressure rise, tubing/line pressure difference and casing/line pressure difference.
- Made the initial state of the control loop user configurable.
- Fixed a bug where the load ratio wasn't displayed correctly.
- Plunger arrival counts are now preserved when a reset command is issued.
- Elapsed Time Flow increments in the Waiting for Plunger Arrival state. Previously Elapsed Time Shut In incremented.
- Changed exe version to 2.5/li>
- RTU applications are at build 342
March 17, 2018
- Fixed a bug with failed TCP connection attempts when the host doesn't exist for the MQTT app.
- Add some events to the diagnostic log for the MQTT app.
- Changed exe version to 2.4
- RTU applications are at build 340
March 16, 2018
- Added support for publishing on change to the MQTT application. You can now select a deadband and the application will publish the value when it changes by more than the deadband. The deadband can be specified as a fixed value or a percentage of the current value.
- Added support for Cirrus Link's Sparkplug B publishing format to the MQTT application. This allows for automated tag generation and metadata transfer from the RTU to the Host in supported applications like Ignition SCADA.
- Added a 30 second holdoff to succesive TCP/IP connection attempts in the MQTT application.
- Fixed a bug where socket resources weren't freed correctly after a failed TCP/IP connection attempt in the MQTT application.
- Changed exe version to 2.3
- RTU applications are at build 338
March 10, 2018
- Alpha release of the Logic application. Logic allows you to implement a matrix of boolean logic.
- Added support for generating Logic reports. A Logic report shows which outputs are driven by which inputs and includes comprehensive information about the application configuration.
- Changed exe version to 2.2
- RTU applications are at build 335
March 7, 2018
- Fixed a bug with generating export files for applications that support extended Modbus configuration
- Changed exe version to 2.1
March 3, 2018
- Added support for generating register overlap reports. This report shows register overlaps within the same app, across multiple apps and can optionally include RealFlo registers.
- Added support to all applications for Extended Modbus Configuration. This feature allows configuration of the application via Modbus on the basis of each configuration group instance, instead of only for the entire application. Configuration registers are no longer multiplexed, and it is also possible to export the current configuration to read-only (input and contact) registers. This feature can reduce the number of registers required for configuration by not using registers for unwanted instances. It also allows for granular control of register placement, since each configuration group instance has its own set of address offsets from the application's base Modbus addresses.
- Added a configuration tab to test screen for applications that support extended configuration. This allows users to test configuration over Modbus without building an HMI or leaving the AppSuite PC Configuration Program.
-
A new version of Plunger Lift:
- Moved flow conditions, shut in conditions and protection settings back to configuration from control.
- Allowed changes of the configuration without reintializing the control loop. This feature, combined with support for extended modbus configuration, allows for changes on the fly while preserving the useful functions (Compare, Version, Change Log) of an AppSuite application.
- Added a 'Waiting for Plunger Arrival' control state. Added a timeout when in this state.The well is shut in immediately when the plunger doesn't arrive within the configured timeout.
- Added the time since the last reset statistics command for each control loop.
- Added a new arrival type of 'unknown'. This is the default arrival type instead of 'no arrival'.
- The manual override coil for each control loop tracks the current state of the sales valve. When manual override is enabled, the state of the valve will be preserved.
- Numerous small bug fixes and enhancements.
- Changed exe version to 2.0
- RTU applications are at build 332
February 20, 2018
- Update Well Test to support Realflo versions 6.95 and 6.96
- Fixed a problem with datalogs where control parameters were sometimes not initialized correctly
- Changed exe version to 1.5
- RTU applications are at build 328
February 4, 2018
- Clear the current cycle stats at the end of a control cycle for Plunger Lift
- Changed exe version to 1.14
- RTU applications are at build 323
January 29, 2018
- Added the ability to exclude configuration registers from a Modbus CSV export.
- Added Extended On Demand to the Datalogs Application. Use a coil to trigger data logging at a configurable period for a configurable duration.
- Added an end of cycle indicator to the Plunger Lift application. A coil is set when a plunger control cycle is complete, which can be used to trigger a datalog.
- Reduced the number of Register Settings configuration groups in Plunger Lift from 8 to 4.
- Changed exe version to 1.13
- RTU applications are at build 321
January 15, 2018
- Fixed a bug which appeared on the Test tab. The values for Modbus coils or contacts would be read multiple times and were not properly de-duplicated, causing Modbus polling to stop
- Changed exe version to 1.12
- RTU applications are at build 318 (no change from previous)
January 7, 2018
- Fixed a bug in all RTU programs where changing the configuration for string parmeters was broken. This primarly affected the MQTT application.
- Fixed the description for the Protection Reason 3 status value in the plunger lift application.
- Added support for Modbus RTU in TCP and Modbus TCP communications protocols
- Changed exe version to 1.11
- RTU applications are at build 318
December 24, 2017
-
Modified Plunger Lift
- Added support for user defined flow condition
- Added support for user defined shut in condition
- Added support for a casing pressure shut in condition
- Added support for a tubing pressure shut in condition
- Changed exe version to 1.10
- RTU applications are at build 314
December 6, 2017
-
Added support for a new version of Plunger Lift.
- Condition enables and setpoints moved to control parameters from configuration parameters. This allows the conditions to be changed at run time without reinitializing the control loop.
- Added support for very early plunger arrival shutdown
- Added support for no plunger arrival shut down
- Added support for very early plunger arrival shut in
- Changed exe version to 1.9
- Changed publish version to 1.14.1
- RTU applications are at build XXX
November 5, 2017
-
Added support for the initial release of Well Test.
- Disabled configuration over Modbus by default for all apps. It's still possible to enable configuration over Modbus, but it's not longer enabled by default. This eliminates register contention with Realflo.
- Changed the default base holding address for all apps. This eliminates contention with Realflo. Take care when enabling configuration via Modbus, becuase the default base addresses for holding registers do not provide enough register space to support configuration.
- Changed exe version to 1.8
- Changed publish version to 1.13.1
- RTU applications are at build 288
October 24, 2017
-
Added support for an updated Datalogs application. This release includes better support for on demand logging. Multiple datalogs can now log on demand via the same coil.
- Changed exe version to 1.6
- Changed publish version to 1.11.1
October 20, 2017
-
Added Telepace Export feature. The Modbus map can be exported in Telepace Studio tags format.
- Changed exe version to 1.5
- Changed publish version to 1.10.1
September 10, 2017
-
Changed the URL for the RTU programs from a constant value regardless of version to a different URL per version.
This prevents old content from being cached by the CDN when new RTU programs are published. This will
require an update to the PC application each time new RTU programs are published, which is probably okay.
- Released build 270 of the RTU programs. This includes support for SCADAPack 4203.
- Changed exe version to 1.4
- Changed publish version to 1.9.1
September 10, 2017
- Fixed a bug where serial communications didn't work on the Test tab.
- Changed exe version to 1.3
- Changed publish version to 1.8.1
September 5, 2017
- Added the ability more easily create ethernet and serial communications settings. A keyboard with an insert key is no longer required.
- Changed exe version to 1.2
- Changed publish version to 1.7.1
August 30, 2017
- Added release notes
- Changed exe version to 1.1
- Changed publish version to 1.6.1